553 research outputs found

    An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Get PDF
    This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW) sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT) was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC) was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN) applications

    Exploring the Identification of Expertise: An Experiment in a Computer Software Corporation

    Get PDF
    People recognize and express their expertise in several ways. In one way, workers can build personal profile to list their expertise. They recall their working experience and write some keyword terms in their personal profiles. In the other way, workers can build expertise in extracting from any documents they provided that includes studying documents, working documents or published papers. We want to know how the workers in the computer software corporation recognize and identify their expertise and explore the heuristics in identification of the expertise. We made an experiment comprised the above methods and invited 25 persons in a computer software corporation to participate and explore how they identify their expertise. During the experiment process, we found that (1) for most people, it’s hard to tell what expertise they completely have without any hint; (2) except these two ways, researchers or practitioners must innovate other methods to identify or elicit human’s expertise; (3) expertise in particular domain is rather than single term, but also multiple complex and related term sets; (4) expertise would be different with different audiences

    Understanding the Impact of Service Failure and Recovery Justice on Consumers’ Satisfaction and Repurchase Intention

    Get PDF
    This research attempts to explore the impacts of different types of justice and their interactions on the satisfaction toward service failure recovery. We attempt to classify justices into hygiene, motivator, or asymmetric variable, based on the concept of asymmetric effect and two factors theory proposed by Herzberg. Specifically, we predict that procedural and distributive justices are hygiene or performance factor and interpersonal justice is motivator. In addition, based on expectancy-disconfirmation theory (EDT), we also attempt to understand the interaction between paired justices by arguing that motivator can generate more effect when hygiene factor or performance factors meet initial expectation. An experiment, with 3x2x2 between-subjects factorial design consisting of three factors to represent different levels of justice provided by online retailer, will be conducted to test the proposed hypotheses. A two-step approach will be used to (1) confirmation the types (hygiene, performance, or motivator) that each justice dimension belongs to, (2) understand the impact of each justice on satisfaction, and (3) test whether motivator will generate more effect when hygiene and performance factor are satisfied

    Charge-Trapping Devices Using Multilayered Dielectrics for Nonvolatile Memory Applications

    Get PDF
    Charge-trapping devices using multilayered dielectrics were studied for nonvolatile memory applications. The device structure is Al/Y2O3/Ta2O5/SiO2/Si (MYTOS). The MYTOS field effect transistors were fabricated using Ta2O5 as the charge storage layer and Y2O3 as the blocking layer. The electrical characteristics of memory window, program/erase characteristics, and data retention were examined. The memory window is about 1.6 V. Using a pulse voltage of 6 V, a threshold voltage shift of ~1 V can be achieved within 10 ns. The MYTOS transistors can retain a memory window of 0.81 V for 10 years

    Neocaridina fonticulata, a new land-locked freshwater shrimp from Hengchun Peninsula, Taiwan (Decapoda, Caridea, Atyidae)

    Get PDF
    A new species of land-locked freshwater shrimp, Neocaridina fonticulata sp. n. (Atyidae), is described from Kenting, Hengchun Peninsula, Pingtung County, southern Taiwan. This new species can be distinguished from its congeners by rostrum structure, pereiopods, and male first and second pleopods. The molecular evidence of mitochondrial cytochrome oxidase subunit I (COI) also supports the establishment of a new species. This is the third endemic species of Neocaridina known from Taiwan

    Northern Hemisphere Urban Heat Stress and Associated Labor Hour Hazard from ERA5 Reanalysis

    Get PDF
    Increasing surface air temperature is a fundamental characteristic of a warming world. Rising temperatures have potential impacts on human health through heat stress. One heat stress metric is the wet-bulb globe temperature, which takes into consideration the effects of radiation, humidity, and wind speed. It also has broad health and environmental implications. This study presents wet-bulb globe temperatures calculated from the fifth-generation European Centre for Medium-Range Weather Forecasts atmospheric reanalysis and combines it with health guidelines to assess heat stress variability and the potential for reduction in labor hours over the past decade on both the continental and urban scale. Compared to 2010–2014, there was a general increase in heat stress during the period from 2015 to 2019 throughout the northern hemisphere, with the largest warming found in tropical regions, especially in the northern part of the Indian Peninsula. On the urban scale, our results suggest that heat stress might have led to a reduction in labor hours by up to ~20% in some Asian cities subject to work–rest regulations. Extremes in heat stress can be explained by changes in radiation and circulation. The resultant threat is highest in developing countries in tropical areas where workers often have limited legal protection and healthcare. The effect of heat stress exposure is therefore a collective challenge with environmental, economic, and social implications.publishedVersio

    Unusual case of spontaneous uterine rupture in a single gestational primipara

    Get PDF
    AbstractSpontaneous rupture of the primiparous uterus is a rare but catastrophic obstetrical emergency. It is usually associated with prior uterine surgery, trauma, or placental abnormality. To remind physicians to include this condition in their differential diagnosis of acute abdominal pain in pregnant patients, we describe an interesting case of spontaneous uterine rupture that clinically mimicked bowel perforation. A 27-year-old single primiparous pregnant woman presented with sudden onset of severe abdominal pain and peritoneal signs, with absence of vaginal bleeding at 26 weeks’ gestation. The usual risk factors for uterine rupture, such as advanced maternal age, scarred uterus due to mode of previous delivery, or unusual pregnancy, were not present in our patient. Based on clinical examination, abdominal sonography and magnetic resonance imaging, uterine rupture was suspected and eventually confirmed at exploratory laparotomy. No uterine pathological abnormality was noted on the microscopic examination The preterm newborn expired after surgery. Since surgical intervention is the only definitive treatment, emergency physicians should be aware of this rare complication. Emergency physicians should be aware of spontaneous uterine rupture in pregnant patients, even in the absence of risk factors

    Development of a Portable Electronic Nose System for the Detection and Classification of Fruity Odors

    Get PDF
    In this study, we have developed a prototype of a portable electronic nose (E-Nose) comprising a sensor array of eight commercially available sensors, a data acquisition interface PCB, and a microprocessor. Verification software was developed to verify system functions. Experimental results indicate that the proposed system prototype is able to identify the fragrance of three fruits, namely lemon, banana, and litchi

    Volumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To compare the RapidArc plan for primary hepatocellular carcinoma (HCC) with 3-D conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans using dosimetric analysis.</p> <p>Methods</p> <p>Nine patients with unresectable HCC were enrolled in this study. Dosimetric values for RapidArc, IMRT, and 3DCRT were calculated for total doses of 45~50.4 Gy using 1.8 Gy/day. The parameters included the conformal index (CI), homogeneity index (HI), and hot spot (V<sub>107%</sub>) for the planned target volume (PTV) as well as the monitor units (MUs) for plan efficiency, the mean dose (D<sub>mean</sub>) for the organs at risk (OAR) and the maximal dose at 1% volume (D<sub>1%</sub>) for the spinal cord. The percentage of the normal liver volume receiving ≥ 40, > 30, > 20, and > 10 Gy (V<sub>40 Gy</sub>, V<sub>30 Gy</sub>, V<sub>20 Gy</sub>, and V<sub>10 Gy</sub>) and the normal tissue complication probability (NTCP) were also evaluated to determine liver toxicity.</p> <p>Results</p> <p>All three methods achieved comparable homogeneity for the PTV. RapidArc achieved significantly better CI and V<sub>107% </sub>values than IMRT or 3DCRT (<it>p </it>< 0.05). The MUs were significantly lower for RapidArc (323.8 ± 60.7) and 3DCRT (322.3 ± 28.6) than for IMRT (1165.4 ± 170.7) (<it>p </it>< 0.001). IMRT achieved a significantly lower D<sub>mean </sub>of the normal liver than did 3DCRT or RapidArc (<it>p </it>= 0.001). 3DCRT had higher V<sub>40 Gy </sub>and V<sub>30 Gy </sub>values for the normal liver than did RapidArc or IMRT. Although the V<sub>10 Gy </sub>to the normal liver was higher with RapidArc (75.8 ± 13.1%) than with 3DCRT or IMRT (60.5 ± 10.2% and 57.2 ± 10.0%, respectively; <it>p </it>< 0.01), the NTCP did not differ significantly between RapidArc (4.38 ± 2.69) and IMRT (3.98 ± 3.00) and both were better than 3DCRT (7.57 ± 4.36) (<it>p </it>= 0.02).</p> <p>Conclusions</p> <p>RapidArc provided favorable tumor coverage compared with IMRT or 3DCRT, but RapidArc is not superior to IMRT in terms of liver protection. Further studies are needed to establish treatment outcome differences between the three approaches.</p
    • …
    corecore